首页 / 院系成果 / 成果详情页

Is whole-body fluorine-18 fluorodeoxyglucose PET/CT plus additional pelvic images (oral hydration-voiding-refilling) useful for detecting recurrent bladder cancer?  期刊论文  

  • 编号:
    03afffe1-c172-4a6e-a6a2-a86e7b779371
  • 作者:
    Yang, Zhongyi(杨忠毅)#[1,2]Cheng, Jingyi(程竞仪)[1,2]Pan, Lingling[1,2];Hu, Silong[1,2];Xu, Junyan(徐俊彦)[1,2]Zhang, Yongping[1,2];Wang, Mingwei(王明伟)[1,2]Zhang, Jianping[1,2];Ye, Dingwei(叶定伟)[2,3]Zhang, Yingjian(章英剑)*[1,2]
  • 语种:
    English
  • 期刊:
    ANNALS OF NUCLEAR MEDICINE ISSN:0914-7187 2012 年 26 卷 7 期 (571 - 577) ; AUG
  • 收录:
  • 关键词:
  • 摘要:

    Because of the urinary excretion of fluorine-18 fluorodeoxyglucose (F-18-FDG), FDG-PET or PET/CT is thought of little value in patients with bladder cancer. The purpose of our study was to investigate the value of F-18-FDG PET/CT with additional pelvic images in detection of recurrent bladder cancers. From December 2006 to August 2010, 35 bladder cancer patients (median age 56 years old, ranging from 35 to 96) underwent routine F-18-FDG PET/CT. To better detect bladder lesions, a new method called as oral hydration-voiding-refilling was introduced, which included that all the patients firstly received oral hydration, then were required to void frequently and finally were demanded to hold back urine when the additional pelvic images were scanned. Lesions were confirmed by either histopathology or clinical follow-up for at least 6 months. Finally, 12 recurrent cases of 35 patients were confirmed by cystoscope. PET/CT correctly detected 11 of them. Among these 11 true positive patients, 5 patients (45.5 %) were detected only after additional pelvic images. Lichenoid lesions on the bladder wall were missed, which caused 1 false negative result. All three false positive cases were testified to be inflammatory tissues by cystoscope. Therefore, the sensitivity, specificity and accuracy of PET/CT were 91.7 % (11/12), 87.0 % (20/23) and 88.6 % (31/35), respectively. PET/CT with additional pelvic images can highly detect recurrent lesions in residual bladder tissues. Our method with high accuracy and better endurance could be potentially applied.

  • 推荐引用方式
    GB/T 7714:
    Yang Zhongyi,Cheng Jingyi,Pan Lingling, et al. Is whole-body fluorine-18 fluorodeoxyglucose PET/CT plus additional pelvic images (oral hydration-voiding-refilling) useful for detecting recurrent bladder cancer? [J].ANNALS OF NUCLEAR MEDICINE,2012,26(7):571-577.
  • APA:
    Yang Zhongyi,Cheng Jingyi,Pan Lingling,Hu Silong,&Zhang Yingjian.(2012).Is whole-body fluorine-18 fluorodeoxyglucose PET/CT plus additional pelvic images (oral hydration-voiding-refilling) useful for detecting recurrent bladder cancer? .ANNALS OF NUCLEAR MEDICINE,26(7):571-577.
  • MLA:
    Yang Zhongyi, et al. "Is whole-body fluorine-18 fluorodeoxyglucose PET/CT plus additional pelvic images (oral hydration-voiding-refilling) useful for detecting recurrent bladder cancer?" .ANNALS OF NUCLEAR MEDICINE 26,7(2012):571-577.
浏览次数:3 下载次数:0
浏览次数:3
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部