International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009  期刊论文  

  • 编号:
    0658346b-f2c7-4e8e-81f7-94add0ca5f5d
  • 作者:
    Rosenthal, Victor D.[1] Hu Bijie[2] Maki, Dennis G.[3] Mehta, Yatin[4] Apisarnthanarak, Anucha[5] Medeiros, Eduardo A.[6] Leblebicioglu, Hakan[7] Fisher, Dale[8] AlvarezMoreno, Carlos[9] Abu Khader, Ilham[10] Gonzalez Martinez, Marisela Del Rocio[11] Cuellar, Luis E.[12] Anne NavoaNg, Josephine[13] Abouqal, Redouane[14] Guanche Garcell, Humberto[15] Mitrev, Zan[16] Pirez Garcia, Maria Catalina[17] Hamdi, Asma[18] Duenas, Lourdes[19] Cancel, Elsie[20] Gurskis, Vaidotas[21] Rasslan, Ossama[22] Ahmed, Altaf[23] Kanj, Souha S.[24] Chavarria Ugalde, Olber[25] Mapp, Trudell[26] Raka, Lul[27,28] Meng, Cheong Yuet[29,30] Le Thi Anh Thu[31] Ghazal, Sameeh[32] Gikas, Achilleas[33] Pazmino Narvaez, Leonardo[34] Mejia, Nepomuceno[35] Hadjieva, Nassya[36] Elanbya, May Osman Gamar[37] Guzman Siritt, Maria Eugenia[38] Jayatilleke, Kushlani[39]
  • 语种:
    English
  • 期刊:
    AMERICAN JOURNAL OF INFECTION CONTROL ISSN:0196-6553 2012 年 40 卷 5 期 (396 - 407) ; JUN
  • 收录:
  • 关键词:
  • 摘要:

    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright (C) 2011 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  • 推荐引用方式
    GB/T 7714:
    Rosenthal Victor D.,Hu Bijie,Maki Dennis G., et al. International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009 [J].AMERICAN JOURNAL OF INFECTION CONTROL,2012,40(5):396-407.
  • APA:
    Rosenthal Victor D.,Hu Bijie,Maki Dennis G.,Mehta Yatin,&Jayatilleke Kushlani.(2012).International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009 .AMERICAN JOURNAL OF INFECTION CONTROL,40(5):396-407.
  • MLA:
    Rosenthal Victor D., et al. "International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009" .AMERICAN JOURNAL OF INFECTION CONTROL 40,5(2012):396-407.
浏览次数:7 下载次数:0
浏览次数:7
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部