首页 / 院系成果 / 成果详情页

Subacute Effects of Rose Bengal/Green Light Cross Linking on Rabbit Thin Corneal Stability and Safety  期刊论文  

  • 编号:
    34246cba-130d-4b04-972c-b0372b4e7fc2
  • 作者:
    Wang, Ti[1];Zhu, Lu[2];Zhu, Jingyin(朱静吟)*[2]Peng, Yinbo[3];Shen, Nianci[2];Yu, Yan[4];Yao, Min[3];
  • 语种:
    English
  • 期刊:
    LASERS IN SURGERY AND MEDICINE ISSN:0196-8092 2018 年 50 卷 4 期 (324 - 332) ; APR
  • 收录:
  • 关键词:
  • 摘要:

    Background and Purpose: The purpose of this study was to investigate the subacute effects of Rose Bengal (RB) and 532nm green light-induced photochemical crosslinking (RB-PCL) on rabbit thin corneal stability and safety in vivo. Materials and Methods: Rabbit thin corneal models with 250 mmthickness were created by photorefractive keratectomy surgery. Photochemical crosslinking with green light (wavelength 532 nm) at an illumination intensity of 0.4 W/cm 2 for 250 s (100 J/cm(2)) was performed, followed by antibiotic treatment and slit lamp monitoring for four weeks. At the end of week four, corneal biomechanical stiffness, biochemical resistance to collagenase digestion, and corneal cellular morphology were assessed. The penetration depth of RB into the corneal stromal was measured by confocal microscopy. Results: At the end of week 4, RB-PCL had increased corneal tensile strength by an average 2.5-fold and had extended the corneal collagenase digestion time from 10.17 +/- 2.93 to 15.83 +/- 2.64 days. RB penetrated approximately 90 mm into the corneal stroma. RB-PCL did not alter the corneal endothelial and stromal morphology at the cellular or subcellular levels, according to electron microscopic examination. Conclusions: RB and 532nm green light irradiation effectively induced crosslinking in rabbit thin cornea, by increasing both the biomechanical stiffness and the biochemical resistance without evidence of morphological damage to the corneal endothelium or stroma. This study demonstrated the efficacy of RB-PCL in strengthening thin cornea at four weeks after the treatment, providing a potential and possibly better option for treating corneal ectasia disorders in cases where corneal thickness is less than 400 mu m. Lasers Surg. Med. 50: 324-332, 2018. (c) 2017 Wiley Periodicals, Inc.

  • 推荐引用方式
    GB/T 7714:
    Wang Ti,Zhu Lu,Zhu Jingyin, et al. Subacute Effects of Rose Bengal/Green Light Cross Linking on Rabbit Thin Corneal Stability and Safety [J].LASERS IN SURGERY AND MEDICINE,2018,50(4):324-332.
  • APA:
    Wang Ti,Zhu Lu,Zhu Jingyin,Peng Yinbo,&Yao Min.(2018).Subacute Effects of Rose Bengal/Green Light Cross Linking on Rabbit Thin Corneal Stability and Safety .LASERS IN SURGERY AND MEDICINE,50(4):324-332.
  • MLA:
    Wang Ti, et al. "Subacute Effects of Rose Bengal/Green Light Cross Linking on Rabbit Thin Corneal Stability and Safety" .LASERS IN SURGERY AND MEDICINE 50,4(2018):324-332.
浏览次数:7 下载次数:0
浏览次数:7
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部