首页 / 院系成果 / 成果详情页

Computed Tomography Perfusion Imaging Detection of Microcirculatory Dysfunction in Small Intestinal Ischemia-Reperfusion Injury in a Porcine Model  期刊论文  

  • 编号:
    43b768d8-02e5-4f11-8e45-ec3f5b1b4424
  • 作者:
    Shi, Haifeng[1,2];Li, Ruokun(李若坤)[2]Qiang, Jinwei[2];Li, Ying[2];Wang, Li(王丽)[3]Sun, Rongxun(孙荣勋)[4]
  • 语种:
    English
  • 期刊:
    PLOS ONE ISSN:1932-6203 2016 年 11 卷 7 期 ; JUL 26
  • 收录:
  • 摘要:

    Objective To evaluate multi-slice computed tomography (CT) perfusion imaging (CTPI) for identifying microcirculatory dysfunction in small intestinal ischemia-reperfusion (IR) injury in a porcine model. Materials and Methods Fifty-two pigs were randomly divided into 4 groups: (1) the IR group (n = 24), where intestinal ischemia was induced by separating and clamping the superior mesenteric artery (SMA) for 2 h, followed by reperfusion for 1, 2, 3, and 4 h (IR-1h, IR-2h, IR-3h, and IR-4h; n = 6, respectively); (2) the sham-operated (SO) group (n = 20), where the SMA was separated without clamping and controlled at postoperative 3, 4, 5, and 6 h (SO-3h, SO-4h, SO-5h, and SO-6h; n = 5, respectively); (3) the ischemia group (n = 4), where the SMA was separated and clamped for 2 h, without reperfusion, and (4) baseline group (n = 4), an additional group that was not manipulated. Small intestinal CTPI was performed at corresponding time points and perfusion parameters were obtained. The distal ileum was resected to measure the concentrations of malondialdehyde (MDA) and superoxide dismutase (SOD) and for histopathological examination. Results The perfusion parameters of the IR groups showed significant differences compared with the corresponding SO groups and the baseline group (before ischemia). The blood flow (BF), blood volume (BV), and permeability surface (PS) among the 4 IR groups were significantly different. BF and BV were significantly negatively correlated with MDA, and significantly positively correlated with SOD in the IR groups. Histopathologically, the effects of the 2-h ischemic loops were not significantly exacerbated by reperfusion. Conclusion CTPI can be a valuable tool for detecting microcirculatory dysfunction and for dynamic monitoring of small intestinal IR injury.

  • 推荐引用方式
    GB/T 7714:
    Shi Haifeng,Li Ruokun,Qiang Jinwei, et al. Computed Tomography Perfusion Imaging Detection of Microcirculatory Dysfunction in Small Intestinal Ischemia-Reperfusion Injury in a Porcine Model [J].PLOS ONE,2016,11(7).
  • APA:
    Shi Haifeng,Li Ruokun,Qiang Jinwei,Li Ying,&Sun Rongxun.(2016).Computed Tomography Perfusion Imaging Detection of Microcirculatory Dysfunction in Small Intestinal Ischemia-Reperfusion Injury in a Porcine Model .PLOS ONE,11(7).
  • MLA:
    Shi Haifeng, et al. "Computed Tomography Perfusion Imaging Detection of Microcirculatory Dysfunction in Small Intestinal Ischemia-Reperfusion Injury in a Porcine Model" .PLOS ONE 11,7(2016).
浏览次数:2 下载次数:0
浏览次数:2
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部