首页 / 院系成果 / 成果详情页

No Change in Anterior Chamber Dimensions After Femtosecond LASIK for Hyperopia  期刊论文  

  • 编号:
    74518704-266c-49af-bcb4-74112b12f747
  • 作者:
  • 语种:
    English
  • 期刊:
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE ISSN:1542-2321 2015 年 41 卷 3 期 (160 - 163) ; MAY
  • 收录:
  • 关键词:
  • 摘要:

    Objective: To compare the changes in anterior chamber volume (ACV), anterior chamber depth (ACD) and anterior chamber angle (ACA) before and 6 months after femtosecond laser in situ keratomileusis (LASIK) for hyperopia using the Pentacam HR device. Methods: A total of 24 eyes of 24 consecutive hyperopic patients undergoing femtosecond LASIK were examined preoperatively and 6 months postoperatively. Anterior chamber volume; ACDs in the central, superior, inferior, nasal, and temporal quadrants; and ACA were measured using the Pentacam HR device. Comparisons of preoperative versus postoperative values were performed using paired Student t test. Linear regression analysis was performed to evaluate correlations between ACV change, central ACD change, age, and attempted maximum ablation depth. Results: Preoperative and postoperative mean ACVs were 153.6 and 158.2 mu L, respectively. Preoperative and postoperative mean ACDs were 2.81, 2.28, 2.53, 2.16, and 2.61 mm, and 2.84, 2.31, 2.54, 2.16, and 2.65 mm, respectively. Preoperative and postoperative mean ACAs were 33.3 degrees and 32.0 degrees, respectively. There were not statistically significant differences in ACV, ACDs, and ACA from preoperatively to 6 months after femtosecond LASIK (all P>0.05). The change of central ACD was correlated significantly with age at 6 months postoperatively (R-2=0.18, P=0.039). Conclusions: Anterior chamber profiles, including ACV, ACA, and central and peripheral ACDs did not significantly change after femtosecond LASIK for hyperopia.

  • 推荐引用方式
    GB/T 7714:
    Zhou Xiaodong,Li Tao,Chen Zhi, et al. No Change in Anterior Chamber Dimensions After Femtosecond LASIK for Hyperopia [J].EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE,2015,41(3):160-163.
  • APA:
    Zhou Xiaodong,Li Tao,Chen Zhi,Niu Lingling,&Zhou Zimei.(2015).No Change in Anterior Chamber Dimensions After Femtosecond LASIK for Hyperopia .EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE,41(3):160-163.
  • MLA:
    Zhou Xiaodong, et al. "No Change in Anterior Chamber Dimensions After Femtosecond LASIK for Hyperopia" .EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE 41,3(2015):160-163.
浏览次数:8 下载次数:0
浏览次数:8
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部