首页 / 院系成果 / 成果详情页

Multi-analyte method development for analysis of brominated flame retardants (BFRs) and PBDE metabolites in human serum  期刊论文  

  • 编号:
    74968274-ed12-48b1-bc3b-e7aa22ef517c
  • 作者:
    Lu, Dasheng[1,2];Jin, Yu'e[1];Feng, Chao[1];Wang, Dongli[3];Lin, Yuanjie[1];Qiu, Xinlei[1];Xu, Qian[1];Wen, Yimin[1];She, Jianwen[3];Wang, Guoquan(汪国权)*[1]Zhou, Zhijun(周志俊)[2]
  • 语种:
    English
  • 期刊:
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY ISSN:1618-2642 2017 年 409 卷 22 期 (5307 - 5317) ; SEP
  • 收录:
  • 关键词:
  • 摘要:

    Commonly, analytical methods measuring brominated flame retardants (BFRs) of different chemical polarities in human serum are labor consuming and tedious. Our study used acidified diatomaceous earth as solid-phase extraction (SPE) adsorbent and defatting material to simultaneously determine the most abundant BFRs and their metabolites with different polarities in human serum samples. The analytes include three types of commercial BFRs, tetrabromobisphenol A (TBBPA), hexabromocyclododecane (HBCD) isomers, and polybrominated biphenyl ethers (PBDEs), and dominant hydroxylated BDE (OH-PBDE) and methoxylated BDE (MeO-PBDE) metabolites of PBDEs. The sample eluents were sequentially analyzed for PBDEs and MeO-BDEs on online gel permeation chromatography/gas chromatography-electron capture-negative ionization mass spectrometry (online GPC GC-ECNI-MS) and for TBBPA, HBCD, and OH-BDEs on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method recoveries were 67-134% with a relative standard deviation (RSD) of less than 20%. Method detection limits (MDLs) were 0.30-4.20 pg/mL fresh weight (f.w.) for all analytes, except for BDE-209 of 16 pg/mL f.w. The methodology was also applied in a pilot study, which analyzed ten real samples from healthy donors in China, and the majority of target analytes were detected with a detection rate of more than 80%. To our knowledge, it is the first time for us in effectively determining BFRs of most types in one aliquot of human serum samples. This new analytical method is more specific, sensitive, accurate, and time saving for routine biomonitoring of these BFRs and for integrated assessment of health risk of BFR exposure.

  • 推荐引用方式
    GB/T 7714:
    Lu Dasheng,Jin Yu'e,Feng Chao, et al. Multi-analyte method development for analysis of brominated flame retardants (BFRs) and PBDE metabolites in human serum [J].ANALYTICAL AND BIOANALYTICAL CHEMISTRY,2017,409(22):5307-5317.
  • APA:
    Lu Dasheng,Jin Yu'e,Feng Chao,Wang Dongli,&Zhou Zhijun.(2017).Multi-analyte method development for analysis of brominated flame retardants (BFRs) and PBDE metabolites in human serum .ANALYTICAL AND BIOANALYTICAL CHEMISTRY,409(22):5307-5317.
  • MLA:
    Lu Dasheng, et al. "Multi-analyte method development for analysis of brominated flame retardants (BFRs) and PBDE metabolites in human serum" .ANALYTICAL AND BIOANALYTICAL CHEMISTRY 409,22(2017):5307-5317.
浏览次数:2 下载次数:0
浏览次数:2
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部