首页 / 院系成果 / 成果详情页

Multi-targeted interference-free determination of ten beta-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: Comparison with multiple reaction monitoring  期刊论文  

  • 编号:
    e09b475e-866a-41ee-83ae-735963a55e38
  • 作者:
    Gu, HuiWen[1];Wu, HaiLong[1];Yin, XiaoLi[1];Li, Yong[1];Liu, YaJuan[1];Xia, Hui[1];Zhang, ShuRong[1];Jin, YiFeng[1];Sun, XiaoDong[1];Yu, RuQin[1];Yang, PengYuan(杨芃原)[2,3]Lu, HaoJie(陆豪杰)[2,3]
  • 语种:
    English
  • 期刊:
    ANALYTICA CHIMICA ACTA ISSN:0003-2670 2014 年 848 卷 (10 - 24) ; OCT 27
  • 收录:
  • 关键词:
  • 摘要:

    beta-blockers are the first-line therapeutic agents for treating cardiovascular diseases and also a class of prohibited substances in athletic competitions. In this work, a smart strategy that combines three-way liquid chromatography-mass spectrometry (LC-MS) data with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was developed for simultaneous determination of ten beta-blockers in human urine and plasma samples. This flexible strategy proved to be a useful tool to solve the problems of overlapped peaks and uncalibrated interferences encountered in quantitative LC-MS, and made the multi-targeted interference-free qualitative and quantitative analysis of beta-blockers in complex matrices possible. The limits of detection were in the range of 2.0 x 10 (5)-6.2 x 10 (3) mu g mL (1), and the average recoveries were between 90 and 110% with standard deviations and average relative prediction errors less than 10%, indicating that the strategy could provide satisfactory prediction results for ten beta-blockers in human urine and plasma samples only using liquid chromatography hyphenated single-quadrupole mass spectrometer in full scan mode. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring (MRM) method. T-test demonstrated that there are no significant differences between the prediction results of the two methods. Considering the advantages of fast, low-cost, high sensitivity, and no need of complicated chromatographic and tandem mass spectrometric conditions optimization, the proposed strategy is expected to be extended as an attractive alternative method to quantify analyte(s) of interest in complex systems such as cells, biological fluids, food, environment, pharmaceuticals and other complex samples. (C) 2014 Elsevier B.V. All rights reserved.

  • 推荐引用方式
    GB/T 7714:
    Gu Hui-Wen,Wu Hai-Long,Yin Xiao-Li, et al. Multi-targeted interference-free determination of ten beta-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: Comparison with multiple reaction monitoring [J].ANALYTICA CHIMICA ACTA,2014,848:10-24.
  • APA:
    Gu Hui-Wen,Wu Hai-Long,Yin Xiao-Li,Li Yong,&Lu Hao-Jie.(2014).Multi-targeted interference-free determination of ten beta-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: Comparison with multiple reaction monitoring .ANALYTICA CHIMICA ACTA,848:10-24.
  • MLA:
    Gu Hui-Wen, et al. "Multi-targeted interference-free determination of ten beta-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: Comparison with multiple reaction monitoring" .ANALYTICA CHIMICA ACTA 848(2014):10-24.
浏览次数:1 下载次数:0
浏览次数:1
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部